Frequently asked questions
The questions our technical office in Bologna is asked most often, grouped under five headings. Can’t find yours? Write to us on WhatsApp or through the form: we reply within 24 hours.
ISO 9001:2015 certified · ATEX versions availableTechnical reply within 24 hours
How it works
How does a positive displacement gear pump work?
Two gears rotate inside a closed body: the fluid fills the spaces between the teeth on the suction side, is carried round along the walls and pushed out on the delivery side, where the teeth mesh again. Each revolution moves an almost constant volume, the displacement.
When is a gear pump better than a centrifugal pump?
With viscous fluids. Thin liquids such as petrol can be pumped too, but from the viscosity of oils, molasses, resins and creams upwards a gear pump is practically the only sensible choice, because a centrifugal pump loses flow rate and efficiency as viscosity rises.
How does it differ from lobe and screw pumps?
They are no harder to clean, but they perform poorly, starting with the fact that they are self-priming only in theory. An external gear pump genuinely primes and holds its flow rate and pressure with thick fluids.
Is the pump reversible?
Yes, every series except the FX: reversing the direction of rotation swaps suction and delivery, so the same pump empties pipework or loads and unloads.
Flow rate and speed
How is the flow rate calculated?
Theoretical flow rate = displacement × speed. A pump with 503 cm³/rev at 950 rpm delivers about 478 l/min. The pump selector does this calculation for every model.
Does the flow rate change if the delivery pressure rises?
The real flow rate is partially affected by the delivery pressure. With viscous fluids the reduction is minimal, with volatile fluids it is more significant, but in any case nothing like that of a centrifugal pump.
Can I regulate the flow rate?
Yes, with an inverter: varying the speed of rotation gives you the instantaneous flow rate you want. Dosing, that is delivering a precise quantity and stopping at the right moment, is the job of the plant’s control system.
Why should viscous fluids be pumped at low speed?
Because at high speed the spaces between the teeth do not have time to fill: the flow rate drops, the pump becomes noisy and wears. For molasses, resins, creams and bitumen we use low speeds, often with a geared motor.
What is the maximum flow rate of the range?
From the 0.47 l/min of the 1 ZV at 450 rpm up to about 2,770 l/min of the 5 NAV at 1,450 rpm. Each model has its own maximum speed, shown in the series tables.
Installation
Is the pump self-priming?
Yes. An external gear pump draws even with an empty suction line, provided the body is wet. The suction lift achievable depends on viscosity, temperature and pipework: tell us yours and we will check it.
Can it run in reverse?
Every series except the FX is reversible: reversing the rotation swaps suction and delivery.
Can it run dry?
Only for brief moments, for example at start-up. The fluid lubricates the gears and the bushes: prolonged dry running damages them.
How should the suction line be made?
Short, with a diameter no smaller than the pump port, few bends and no air pockets. For viscous fluids an oversized diameter is advisable and, if the product cools, a heated or insulated line.
Do I need a filter?
Yes, if the fluid may contain foreign bodies: a coarse-mesh strainer on the suction side protects the gears without throttling the pump. For products loaded with solids, ask us for the right mesh size.
What is cavitation and how is it avoided?
If the suction pressure falls too low, vapour bubbles form in the fluid and implode on the delivery side: noise, vibration and wear. It is avoided with a short, wide suction line, a speed suited to the viscosity and sufficient head on the suction side.
Fluids and materials
Cast iron or stainless steel?
Cast iron for oils, bitumen, resins and most industrial fluids; AISI 316 stainless steel for food, cosmetic, pharmaceutical and corrosive fluids. The CR series comes in both materials; the FX is entirely in stainless steel machined from solid.
How is the pump heated for bitumen, chocolate or waxes?
With the thermal-oil heating jacket of the CR series, which surrounds the pumping chamber. The SB series, immersed in the hot fluid, is heated by the fluid itself and has internal thermal-oil channels or, alternatively, electric cartridge heaters. Insulating the pump is preferable but not compulsory.
What is the difference between electric cartridges and a hot spot?
Cartridge heaters warm the pump body quickly; heating with a hot spot calls for a much longer pre-heating time. In both cases the pump restarts without strain on the gears.
Do you pump abrasive fluids or fluids loaded with solids?
Yes, at low speed and with suitable materials. Tell us the type of solids and their percentage: our technical office chooses the materials and the speed.
Is the pump suitable for food?
The FX series is entirely in stainless steel, dismantles completely in a few minutes for cleaning and can be washed in C.I.P. For chocolate and creams it is also available with a heating or cooling jacket.
Certifications and supply
Are the pumps certified?
Yes. Quality system certified to ISO 9001:2015 by SGS since 2004 and CE marking under the Machinery Directive 2006/42/EC. Certificates are available on request.
Are ATEX pumps available?
Yes, for zones 1, 2, 21 and 22 with temperature classes T1–T4, technical file lodged with TÜV. Zones 0 and 20 and classes T5 and T6 are not available.
How is the pump supplied?
Bare shaft (foot mounted B3 or flange mounted B14), as an electric pump unit on a baseplate with coupling and guard, or as a geared motor unit for low speeds.
How quickly do you reply?
Within 24 working hours, with a technical reply from the office that designs the pumps: proposed model, speed, drive and quotation. We reply in English.
Do you build custom pumps?
Yes. If no catalogue model covers the application, we design and machine a custom version in-house in Bologna, with the ports, materials and footprint you need.
Technical office · reply within 24 hours
Request a technical quote
Fluid, flow rate and temperature: three figures are enough to identify the right model. We reply within 24 working hours.