How the calculation works
A gear pump moves an almost constant volume at every revolution: its displacement. Dividing the required flow rate by the displacement gives the speed needed. The selector discards the models that would have to run below 450 rpm or above their permitted maximum speed.
The real flow rate is partially affected by the delivery pressure: with viscous fluids the reduction is minimal, with thinner fluids it is more noticeable, but it remains nowhere near that of a centrifugal pump. That is why the selection has to be confirmed against the data of your plant.
Why viscous fluids call for low speed
The thicker the fluid, the longer it takes to fill the spaces between the teeth on the suction side. At high speed the pump fills poorly, the flow rate drops and noise and wear set in. For molasses, resins, creams and bitumen we therefore propose the models that deliver the flow rate at the lowest speed, often with a geared motor unit.
After the selection
Clicking Quote next to a model fills in the form with the fluid, the flow rate and the model. Add the temperature, the viscosity if you know it, the delivery pressure and the suction lift: with these data our technical office in Bologna confirms the model, the speed and the drive within 24 hours.